Project Description
Thermoguard Timbercoat provides durable wear, weather and wash resistant fire protection paint for decorative interior and exterior timber surfaces.
Use with SFR Dualcoat.
Complies with Class O, Class 1 and new Fire Regs Standards Class B s1 dO.
When exposed to fire:
- Smoke & Flame Retardant “SFR” Dualcoat releases a vapour to control flamespread, suppress smoke, toxic gasses.
- Thermoguard Timbercoat expands to create a barrier to insulate wood from heat and oxygen to prevent wood burning & fire penetration.
- 1 coat Timbercoat intumescent + 1 coat SFR Dualcoat
- 30 & 60 mins Fire Resistance
- 3 Timbercoat basecoat (5 kg cans) + 1 coat SFR Dualcoat
- White, BS 381C , BS 4800 + RAL colours
- Internal & external (with 2nd coat SFR Dualcoat)
- Saves time and money.
See Data Sheets, Colour Charts and additional information below.
AVAILABLE IN:
20 & 80 square metre for Class 1, O, B, C.
5kg cans for 30, 60 mins.
Thermoguard TIMBERCOAT
CLASS 1 AND CLASS 0 INTUMESCENT PAINT FOR TIMBER
SAFETY DATA SHEET – TIMBERCOAT
30 & 60 mins Fire Resistance to Timber boards, beams & joists
INTERNAL & EXTERNAL
Please refer this to the appropriate Authority for approval.
30 mins. If wood can afford to lose max 3 mm to charring from exposed faces without collapsing, flame penetration or excessive heat penetration apply 3 coats @ 20 sq m per 5 kg each.
If wood can afford to lose 7 mm apply 2 coats @ 20 sq m per 5 kg
60 mins. If joists & beams can afford to lose 7 mm from exposed faces to charring or boards 10mm loss, apply 4 coats @ 28 sq m per 5 kg
Sometimes people are required to achieve 30 minutes(or 60 minutes) to timber cladding fixed to a solid concrete block, brick or fire board wall.
We will Certify 30 or 60 minutes as required + Class O / Class B s1 dO with:
- 2 coats Timbercoat @ 20 sq m per 5 kg
- 1 coat Smoke & Flame Retardant “SFR” Dualcoat (2nd coat external)
Note – For advice email technical@thermoguard.co.uk or call 01142 768008 (2)