Project Description

INTUMESCENT FIRE PROTECTION
Thermoguard Fire Varnish basecoat expands in a fire, creating a fire protective barrier, insulating wood materials from flames, heat and oxygen to prevent flamespread & fire penetration. Fire Varnish Overcoat controls toxic smoke.
FINISH & COVERAGE
- Matt & Satin
- Fire Varnish basecoat – 20 sq m pack
- Clear or Stained Fire Varnish Overcoat – 20 sq m + 80 sq m
SPECIFICATION & APPLICATION
- 1 coat Thermoguard Fire Varnish basecoat
- 1 coat Thermoguard Fire Varnish Overcoat **
** Fruitwoods or damp areas 2 coats FVOvercoat.
EXTERNAL or Stained Varnish – 1 coat FVbasecoat , 2 coats FV External Overcoat.
UKAS FIRE TEST STANDARDS
- BS EN Class B s2 dO
- Class O
Note – For 30 or 60 mins or doors, contact Technical Dept.
STAINED or VARNISHED SURFACES
- Thermoguard Fire Varnish can be applied over abraded normal varnish and a range of stains & dyes. ***
*** Refer to Fire Varnish data sheet on www.thermoguard.co.uk
AVAILABLE IN:
20 sq m + 80 sq m
20 sq m + 80 sq m
THERMOGUARD FIRE VARNISH PROFESSIONAL LACQUER SYSTEM
Class B s2 dO + Class O
Clear, Woodshades & Opaque Lacquer for Spraybooth Application